 Hudco CMP Ceramic Surface
HUDCO CMP CERAMIC SURFACE is the best prevention to expensive failures.
It is a lower viscosity version of Ceramic Rebuild, And is designed to
coat metal equipment subject to corrosion, cavitation and chemical attack
where a "diamond hard", smooth, glassy surface is desired.
Ceramic Surface is excellent when applied to new equipment to further
extend its surface life, especially where fluid dynamics play a major
role.
Ceramic Surface CANNOT be machined; however, it can be ground in localized
areas, if necessary, to obtain clearances.
HUDCO CMP Ceramaic Surface applications include:
- Pumps
- Impellers
- Screw Conveyors
- Valves
- Heat Exchanger Tube Sheets
Properties
- Mixing Ratio: 7:1 by Weight
- Maximum Operating Temperature 250°F
- Pot Life: 20 Minutes
- 100% Cure: 48 hours
- Machinable: No
- ASTM D 695 Compressive Strength: 14,400 PSI
- ASTM D 1002 Lap Shear: 4,450 PSI
- Color - Resin: Blue
- Color - Hardener: Amber
- Color - Mixed: Blue
- Viscosity: Light Paste
- ASTM-C881 Shrinkage: Pass Barcol
- Hardness: 36 Matrix Only
- Specific Gravity: 1.55 Mixed
- Shelf Life: 1 Year
- Coverage: 2.2# Kit - 7.6 Square Feet, 25 Mils. Thick
- 4.4# Kit - 15.2 Square Feet, 25 Mils. Thick
Instructions
Surface Preparation: Roughen surface by grinding or sandblasting (3-5
mil profile). Surface must be completely dry with a minimum surface
temperature of 75°F.
Mixing: Mix 7 parts of Resin to 1 Part of Hardener by weight. Kits
are supplied in the correct ratio. Ensure that the sides of the mixing
container are scraped into the mixture. Mix several minutes, until consistent
color is achieved.
Application: Apply product to prepared surface and use supplied tools
to achieve desired finish.
Curing: At 75°F, product will gel in 20 min. Initial cure will
occur in 6 - 8 hours. Final Cure occurs in 1 Day. Curing can be accelerated
by heating the applied product to 140°F. Product properties will
also be improved by curing at this elevated temperature.
Safety Precautions:
Industrial use only. Keep away from children.
Always use in well ventilated areas. Prolonged exposure to resin or
hardener may cause sensitization and/or dermatitis. If eye contact occurs,
irrigate promptly with clean water for 15 minutes and call physician.
Wash with soap and water any areas of skin which come in contact with
product. In the case of inhalation, remove to fresh air and provide
oxygen if necessary. If ingestion should occur, call a physician at
once.
Storage:
This product has a shelf life of 1 year and must be stored at a temperature
between 70°F and 85°F.
Warranty:
Because the storage, handling and application of these materials are
beyond our control, we can accept no liability for the results of their
use. Our liability is limited only to replacement of any material proven
defective in manufacture.
Download Application Instructions Here
Click Here to Return to Polymers Page
|